The high temperature demands of faster processors are exceeding the limits of conventional heat sink solutions. Fujikura's Cactus Heat Pipe is designed to meet the most demanding thermal cooling applications. Fujikura has extensive thermal cooling experience, including an understanding gained over 110 years in the interconnect industry and 20 years of manufacturing heat pipes.


Cactus Pipe Grid



High Heat Dissipation
Low Thermal Resistance
Same Performance at Any Orientation
Guaranteed 10 year life
Lightweight
High Aspect Ration Fins
Scalable to Fit Applications

CPU for Desktop
CPU for Workstation
CPU for Server
Any Heat Source up to 200 Watts




Heat Pipe
Container material Copper (JIS C 1020T)
Thickness of container 0.3 mm
Wicks Copper fine fiber bundle
Working fluid Pure water
Length 40-300 mm
Allowable operational temperature range 0-200°C
Allowable inclination angle -5° ~ +5°
Coating Ni coating or none


Fins
Material Aluminum plate


Thermal resistance-the velocity of cooling air
Testing results of thermal resistance against the velocity of cooling air are shown. At low cooling air velocity such as 1 m/s, the obtained thermal resistance was 0.50-0.55 K/W. But with cooling air velocity higher than 2.0 m/s, the thermal resistance can be kept below 0.25 K/W at any orientation.

Testing contents of Cactus Heat Pipe
Testing apparatus is shown. Cactus Heat Pipe is heated by electric heater. (testing conditions)
Velocity of cooling air: 1.0 m/s to 3.0 m/s
Inclination angle: 0°, 90°, 180°